logo logo
  • Home
  • JMV
    • About JMV
    • Catalogues
    • Career
    • Privacy Policy
    • Blog / News
  • Products
    • IoT Solutions

      • RDPMS
      • Smart Loco
      • Smart Stations
      • Smart Infrastructure
      • Distributed Optical Fiber Sensing System   
        • Distributed Acoustic Sensing (DAS)
        • Distributed Temperature Sensing (DTS)
      • EOEL

      Electrical Safety Solution

      • Earthing & Bonding   
        • Earthing Rods
        • Earth Enhancement Compound
        • Earthing Pit Covers
        • Exothermic Welding Solution
      • Lightning Protections   
        • Air Terminals
        • Horizontal Conductors
        • Lightning Strike Counter
        • Connecting Accessories
      • Surge Protection   
        • AC Power
        • DC Power
        • Dataline
        • Telecom
        • Radio Communication
        • Load Cell SPD
        • Isolation Spark Gap
      • Smart Monitoring   
        • Surge Analyzer
        • SPD Life Tester
        • Smart Earthing Monitoring System
        • Integrated Voltage & Surge Monitoring
        • Centralized Monitoring System
      • Digital Grounding Module

      Cable Laying Solution

      • Polyolefin Cable Ducts
      • Composite Cable Ducts

      Railway Solution

      • Signalling Products   
        • Relays/SIG Contacts
        • Earth Leakage Detector
      • Telecom Products   
        • IPMPLS
        • Tunnel Communication
      • Rope Screen Door
      • Loco Simulator
      • 3 Phase Loco Propulsion System

      Miscellaneous

      • Bird Flight Divertor
      • Military Cases
      • Cargo Pallets
  • Industries
    • Smart Mobility

      Defence

      Power Transmission & Distribution

      Infrastructure

      Telecommunication

      Oil & Gas

  • Capabilities
  • Contact Us
Home JMV Blog Details

03April

JMV’s SPDs protect against surges, complying with IEC/EN 61643 and IS/IEC 62305-4, with NABL-certified reliability.

The ideal surge protection system is to provide adequate shielding from lightning or switching transients by perfectly bonding and earthing it to ground. Surge protective devices (SPDs) in essence should be able to impart protective functions and performance parameters in order to be suitable for use in corresponding protection concepts under extreme operating conditions. SPDs are the solution for your electrical and electronics equipment, control automation and networking device which are manufactured, tested, and classified according to their own Indian/ International series of product standards.

The true mark of quality for surge protection devices connected to low-voltage power systems and key areas where protection is necessary further must be subjected to the requirements and test methods specified by the latest IEC/EN 61643 and IS/IEC 62305-4.

JMV make transient suppression devices protecting against these electric burst– 
Primary and secondary protection modules made of Metal Oxide Varistors, Gas discharge Tube, silicon avalanche diode, etc. or it can also be a combination of any of these and applicable for lot of new age electrical/ electronic components be it small, delicate and sensitive in every sector – computer system and its peripherals, substations, communication lines, security and surveillance system, electrical equipment, solar industry, oil and gas, wind turbines, etc. 

Class B surge suppressors installed at the main service panel are for protection against surges injected into your facility via direct lightning strike or indirect means through several pathways further acts against the powerful voltage spikes in 10/350 µs whereas Class C series of switching transient suppression unit are connected in parallel to the devices so as to protect the associated device from switching surges of 8/20 µs. There are special type of surge protectors which is a combination of both class B and class C and act against both lightning induced voltage fluctuations and for those induced due to frequent switching activity.

Product Certification and Approvals

Product certification and approval from a NABL accredited testing institute is vitally important as its application is associated with sensitive equipment for which the highest safety and integrity of the SPDs should be ensured. 

The governing requisite placed on SPDs often require extremely complex yet important 23 nos. of tests as per the mandatory standard IEC 61643 that only a few testing laboratories in the world are fully capable of carrying out. At JMV, we have a fully equipped NABL accredited test center for SPD testing as per the obligatory IEC standard. As an Internal Lightning Protection System to protect against Lightning & Switching Surges, we offer a complete range of Surge protection devices complying to IS/IEC 62305-4 of wide voltage and current rating as it is a mandatory recommendation by National Building Code.

Explaining the latest technology which should be adopted with SPD for complete internal and external safety of the structure and upgrading the safety solution - 

Proper earthing system is mandatory where in replacement of Traditional Pipe & Plate Earthing with Salt & Charcoal backfilling, standard is recommending Maintenance free earthing system which is inclusive of Solid Rod technology based low carbon high tensile steel rods molecularly bonded with min. 250 microns copper coating with an earth enhancement material of less than 0.12 ohm-meters as per IS 3043: 2018. Along with which the standard also propose a permanent jointing system i.e. exothermic welding system for buried earthing connections against mechanical joints (Arc Welding, Nut & Bolt and Brazing) as per latest NBC 2016 with which this earthing technology is offering a life of +40 years. 

As a part of infrastructure development and safety regulations, Lightning Protection System as per IS/IEC 62305 standard & National Building Code (NBC 2016) is mandatory which can be installed at the building phase itself or can be installed outside the structure. A latest revision of IS/IEC 62305 standard & National Building Code (NBC 2016)  propose an Air terminal network, down conductor, bonding techniques, maintenance free earthing methods and practices. 

Recent Article

WHY DO WE NEED LIGHTNING PROTECTION SYSTEM
Aug 16, 2024
Stay Ahead of Surge Failures: Introducing the SPD Life Tester
Aug 22, 2024
Get Real-Time Alerts from Smart Earthing Monitoring System
Aug 22, 2024
How to Choose the Right Surge Protector for Your Infrastructure
Sep 07, 2024
Strength Meets Flexibility: The Power of Polyolefin Cable Ducts
Sep 07, 2024
Best Lightning Protection Design for Maximum Safety
Sep 14, 2024
Choosing the Right Surge Protection: Plug-on Neutral vs. Universal SPDs
Sep 23, 2024
Securing Powerlines, Saving Birds: The Power of Diverters
Oct 04, 2024
How Smart Stations are Revolutionizing Rail Safety and Operations
Oct 14, 2024
Enhance Safety with JMV's Free Earthing Design Services Using CDEGS Software
Nov 05, 2024
Free Lightning Protection System Design with JMV LPS Limited using CDEGS Software
Dec 18, 2024
Discover Why SIG Connector Is the Future of Reliable Cable Connections
Jan 04, 2025
A BASIC OVERVIEW OF EXOTHERMICALLY WELDED CONNECTIONS
Jan 30, 2025
Simulation to Perfection: How Loco Simulators Fine-Tune Loco Pilots' Skills
Feb 12, 2025
Intrusion Detection System: How Fiber-Optic Cables Prevent Animal Collisions on Tracks
Feb 25, 2025
Learn About The Basic Technology On Which The SPDs Are Built
Mar 07, 2025
Cable handling with effective usage of cable ducting technology
Mar 19, 2025
Are your SPDs tested and adhering to NBC and IEC Recommendations?
Apr 03, 2025
Understanding Electrical Surges: Causes, Impacts, and Prevention
May 22, 2025
What’s What? Grounding, Earthing and Bonding.
Jun 04, 2025
Surge Protectors Explained: Your First Line of Defense Against Voltage Spikes
Jul 17, 2025
SIG Connector - The Future of Reliable Cable Connections
Sep 08, 2025

Contact Us

W-50, Sector-11, Noida - 201301,
Delhi NCR, India.

+91 9910407059

+91 9910407391

contact@jmv.co.in

enquiry@jmv.co.in

Company

  • Home
  • Products
  • Contact Us

JMV

  • About JMV
  • Catalogues
  • Career
  • Privacy Policy
  • Blog / News

Services

  • Earthing & Lightning Protection System Designing
  • Auditing & Site Survey
  • Lightning Risk Assessment Calculator
tuvindia
Copyright © 2023 JMV | All Rights Reserved.